http://www.windsolarhybridaustralia.x10.mx
********* note: The batteries in use are high temperature batteries 1600 cycles to 30% DOD.
This means at 20 degrees Celsius “the battery is considered full at 13.6v” because of temperature.(Calculated from data sheet for 2.5v type cell for each of the six cells added together)
At 20 deg. Celsius the battery “capacity in AH is lower in rating” at 80% of total model type of battery rating nominated in ah.
These are nominally 40AH so they are now 34AH at 20 deg C.
The Meaning…………….:
Should have set the float-voltage to 13.4v
overcharge setting at: 13.7v
overcharge recovery at 13.5v
windsolarhybridaustralia.x10.mx/12voltwindsolarhybridaustralia.html
[view in full screen in 720p HD if able or 480p resolution]
[Correction of various video details the 300w is a Sun-Share 3 phase 12v 6-blade]
[This shown in video is R and X Technology SF-600-5 3 phase 12v 5-blade]
[Controller (programmable LCD) is a EPWSC06A (200w - 600w Wind) (and 12v 150w Solar) Jiangsu Ecopower Solution Co.,Ltd]
all from “aliexpress”.
[This controller in this video is a LED non-programmable (200w - 600w Wind) (12v 150w Solar) bought on "ebay"]
* * * * * NOTE: Overcharge setting and overcharge recovery setting should be done using Battery model spec. “data sheet” e.g. Batteries “float life-cycle spec. graph” lasting 10 years at 20 deg. Celsius or 25 deg. Celsius will be a specific voltage at that temperature EXAMPLE ONLY 14 volts “is overcharged” at 20 deg. Celsius (and full at 80% “ah” capacity because of temperature), so set to 13.8v as “overcharged recovery”.
Use battery model data sheet graphs to obtain correct setting levels!
“How To” of function settings for 200w-600w LCD MPPT wind solar hybrid controller. Over voltage and recovery, under voltage and recovery, load timer and wattage settings, load auto on off threshold, MPPT start voltage for turbine.
The instruction manual was interesting, because in mentioning voltages for setting MPPT start, it recommended 6vac for 12v turbines and 12 or 10vac for 24v turbine, however it does insinuate and by the controller settings that 0 all the way in 1v increment to 30v is acceptable no matter other settings i.e. 13.7v floating voltage.
A second point about the test, this is only a crude test with the wind turbine up at 5 meters, also the solar panels (sometimes 2 not 3) are on the ground and a guide dog and a pig dog sometimes interfere with the wiring on the ground so not much occurs(sometimes some semi tame ring tail possums whom disagree about my use of the tool shed when i am in there).
In consequence sometimes nothing much is occurring because of wiring mishaps.
see also VIDEO: “(DIY) MPPT Hybrid charge controller Results from MPPT start set aT 12V”
VALUABLE INFO:
NOTE: Unfortunately if you want ANY wind turbine to operate properly should be placed “12 meters up minimum(15 meters ideal)” into the percentile layer above the ground level percentile layer(meteorology) to EVER operate properly whether a tiny 50w turbine or a 5Kw turbine(sworn truth). There is too much turbulence below 12 meters from obstacles. Second, whether free stand or guy wire, there must be NO wobbling vibration of the pole top. Vibration causes the blades to lose vacuum and on return bounce crash into the oncoming wind pressure, this then can lose two three Meters/second speed of air flow, cause its own turbulence situation and even “tip stall”(swing around opposite facing direction suddenly) the turbine and loose massive speed as it did often on the test pole here!!!
More VALUABLE INFO: * read the information text *
see also “(DIY) 400w rated Wind Turbine (600w max.) 1st operation test”
[IMPORTANT NOTE: Recently i have found an inverter that will operate the 32Lt. Microwave at 240v AC from 12v , it requires to be a LF low frequency pure sine wave of 6000w continuous and 12000 watts surge rating - found on ebay DOT com DOT au]
The before mentioned(if in a video here) microwave oven(32 Lt. max – 2300w output convection) ran for a few seconds then switched off. It seems inclusive when at 50 percent power it takes short bursts of 3600w but also drops to 500w intermittently. I then put my PC on the inverter successfully operating software i have written.
Other things operated successfully as test by the inverter (completely) were a 1000w grill element oven(cooked sausages for 1/2 an hour) and a 2300w vacuum cleaner plane sux for 15 minutes(or until battery too low if i want).
Post time: Feb-21-2017